1):
Connect Laptop with PNMTj software with LCT port of Control card:
2): Open PNMTj software
with username “admin”, connection type “Dial Up” & Dialup Entry Name “PNMT
(USB):
3):
On clicking “Login”, following window will appear:
4):
First go to “MAINT” and turn on maintenance, then click “CTRL”, following
window will appear:
5):
Click “Equipment Network Setting”, following window will appear:
6):
Open provided IP Plan. A sample IP Plan is shown below:
7):
In Access network MW IP Plan, CTRL type is either “Root NE” or “NE”.
Select CTRL Type of your link as per IP Plan.
8):
If you select “NE”, then you will have to enter “In Band IP”, “In Band Subnet
Mask” & “In Band Default Gateway”. Click “Radio/EM1/EM2 and enter “In Band
IP” & “In Band Subnet Mask” at these locations:
9):
Click “Routing” and enter “In-Band Default Gateway” there as shown:
10):
If your node is “Root NE”, select “CTRL Type” as “Root NE”, as shown:
11): Click
“Radio/EM2” and enter “In-Band IP” & “In-Band Subnet Mask” there, as shown:
12):
Click “PNMS(EM1)” and enter “North Bound IP address” & “North bound Subnet
Mask” there:
13): Click “Routing” and enter “North bound
Default Gateway” there as shown:
14):
Do not forget to “Execute” each time you enter new entries. After entering all
these entries, go to “CTRL” tab and click “CPU Reset”
NOTE
Resetting the Control module will not affect traffic. The connection to the selected NE will be lost for a few minutes but will be automatically restored.
Resetting the Control module will not affect traffic. The connection to the selected NE will be lost for a few minutes but will be automatically restored.